Literaturverzeichnis

1 Aufrichtig R.: Comparison of low contrast detectability between a digital amorphous silicon and a screen-film based imaging system for thoracic radiography. Med Phys.. 1999, 26, S. 1349-1358

2 Barnes GT, Sones RA, Tesic MM, Morgan DR, Sanders JN.: Detector for dual energy digital radiography. Radiology. 1985, Aug;156(2), S. 537-40

3 Granfors PR, Aufrichtig R, Possin GE, Giambattista BW, Huang ZS, Liu J, Ma B.: Perfor m ance of a 41 x 41 cm2 amorphous silicon flat panel x-ray d e tector designed for angiographic and R&F imaging applications . Med Phys.. 2003, Oct;30(10), S. 2715-26

4 Ho JT, Kruger RA.: . Comparison of dual and single exposure techniques in dual energy chest radiography. Med Phys.. 1989, 16, S. 202-208

5 Jacobson B.: Dichromatic absorption radiography: dichromography. Acta Radiol.. 1953, 39, S. 436-452

6 Kruger RA, Amstrong JD, Sorenson JA, Niklason LT.: Dual energy film subtraction tec h nique for detecting calcification in solitary pulmonary nodules. Radiology. 1981, 14, S. 213

7 Launders JH, Kengyelics SM, Cowen AR.: A comprehensive physical image quality evalu a tion of a selenium based digital x-ray imaging system for thorax radiography . Med Phys.. 1998, Jun;25(6), S. 986-97

8 Lehmann LA, Avarez RE, Macovski A, Brod WR.: Generalized image co m binations in dual kVp digital radiography. Med Phys.. 1981, 5, S. 659-667

9 Naidich DP, Marshall CH, Gribbin C, Arams RS, McCauley DI.: . Low-dose CT of the lungs: preliminary observations. Radiology. 1990, Jun;175(3), S. 729-31

10 Oestmann JW, Greene R, Rhea JT, Rosenthal H, Koenker RM, Tillotson CL, Pearson KD, Hill JW, Velaj RH.: Single exposure Dual Energy Digital Radiography in the detection of pumonary nodules and calcifications. Invest Radiol.. 1989, 24, S. 517-521

11 Rusinek H, Naidich DP, McGuinness G, Leitman BS, McCauley DI, Krinsky GA, Clayton K, Cohen H.: Pulmonary nodule detection: low-dose versus conventional CT. Radiology. 1998 , Oct;209(1), S. 243-9

12 Strotzer M, Gmeinwieser JK, Volk M, Frund R, Seitz J, Feuerbach S.: Dete c tion of simulated chest lesions with normal and reduced radiation dose: co m parison of conventional screen-film radiography and a flat-panel x-ray detector based on amorphous silicon. Invest Radiol.. 1998, 33, S. 98-103

13 Thijssen MA, Thijssen HO, Merx JL, van Woensel MP.: Quality analysis of DSA equipment. Neuroradiology. 1988, 30(6), S. 561-8


© Die inhaltliche Zusammenstellung und Aufmachung dieser Publikation sowie die elektronische Verarbeitung sind urheberrechtlich geschützt. Jede Verwertung, die nicht ausdrücklich vom Urheberrechtsgesetz zugelassen ist, bedarf der vorherigen Zustimmung. Das gilt insbesondere für die Vervielfältigung, die Bearbeitung und Einspeicherung und Verarbeitung in elektronische Systeme.
DiML DTD Version 4.0Zertifizierter Dokumentenserver
der Humboldt-Universität zu Berlin
HTML-Version erstellt am:
14.09.2006