edoc-Server der Humboldt-Universität zu Berlin

Dissertation

Autor(en): Oliver Wendt
Titel: Entwicklung einer spulenintegrierten und automatisch gesteuerten Biopsieeinrichtung zur histologischen Abklärung von Kleintumoren in der MR-Mammadiagnostik
Gutachter: Andreas Hein; Heinz Wörn; Tim Lüth
Erscheinungsdatum: 27.07.2004
Volltext: html (urn:nbn:de:kobv:11-10033127)
pdf (urn:nbn:de:kobv:11-10032902)
Fachgebiet(e): Medizin
Schlagwörter (ger): Brustkrebs, Mamma, Biopsie, Magnetresonanztomographie, MRT, Kernspintomographie, KST, Intervention, Roboter, Manipulator
Schlagwörter (eng): breast cancer, mamma, biopsy, magnetic resonance imaging, MRI, nuclear magnetic resonance, NMR, intervention, robot, manipulator
Einrichtung: Humboldt-Universität zu Berlin, Medizinische Fakultät - Universitätsklinikum Charité
Zitationshinweis: Wendt, Oliver: Entwicklung einer spulenintegrierten und automatisch gesteuerten Biopsieeinrichtung zur histologischen Abklärung von Kleintumoren in der MR-Mammadiagnostik; Dissertation, Humboldt-Universität zu Berlin, Medizinische Fakultät - Universitätsklinikum Charité , publiziert am 27.07.2004, urn:nbn:de:kobv:11-10032902
Metadatenexport: Um den gesamten Metadatensatz im Endnote- oder Bibtex-Format zu speichern, klicken Sie bitte auf den entsprechenden Link. Endnote   Bibtex  
print on demand: Wenn Sie auf dieses Icon klicken, können Sie ein Druckexemplar dieser Publikation bestellen.
Diese Seite taggen: Diese Icons führen auf so genannte Social-Bookmark-Systeme, auf denen Sie Lesezeichen anlegen, persönliche Tags vergeben und Lesezeichen anderer Nutzer ansehen können.
  • connotea
  • del.icio.us
  • Furl
  • RawSugar

Abstract (ger):
Brustkrebs stellt eine der am häufigsten vorkommenden Krebserkrankungen bei Frauen weltweit dar. Jährlich erkranken in Deutschland ca. 47.000 Frauen neu an Brustkrebs, ca. 18.000 fallen dieser Krankheit im gleichen Zeitraum zum Opfer. Die Brustkrebsdiagnostik basiert auf klinische und verschiedene bildgebende Methoden, die Magnetresonanztomographie (MRT) weist dabei die höchste Sensitivität speziell bei der Erkennung kleiner Tumore unter 5 mm auf. Im Hinblick auf zukünftige Verbesserungen der MR-Bildgebung wird bereits vermutet, dass im Jahr 2010 ca. 50% der neudetektierten Brustkrebse kleiner als 10 mm sein werden. Zur Erhöhung der Diagnosesicherheit werden suspekte Läsionen sowie unklare bildgestützte Befunde zusätzlich mittels Biopsie abgeklärt. In Bezug auf den Stand der Technik ist die sichere Biopsie von Tumoren unter 10 mm Größe jedoch schwierig. Mit dem Ziel, die MR-gestützte Biopsie im Hinblick auf eine höhere Effizienz und Präzision zu verbessern, wurde ein neuer Prototyp für minimal invasive Biopsien speziell in geschlossenen MR-Tomographen entwickelt. Dieses MR-kompatible System basiert auf verschiedene Neukonzeptionen, mit einem automatischen Positioniersystem und Biopsieinstrument zur Ausführung der Intervention. Die extrem hohen Anforderungen an dieses System konnten nur durch spezielle Konstruktionen und Kinematiken, sowie durch MR-kompatible Materialien, Aktoren und Sensoren gelöst werden. Das System ist modular aufgebaut und unterstützt Brustbiopsien sowohl von cranial oder caudal im direkten Anschluss an die Tumorerkennung mit einer neuen doppelseitigen MR-Brustspule. Ein großer Vorteil dieses neuen Ansatzes liegt in der hohen Präzision und der Möglichkeit, sowohl die bildgebende Diagnostik als auch die Biopsie während eines Untersuchungstermines durchzuführen. Die vorklinische Erprobung in einem 1,5 T Hochfeld-MRT zeigte, dass die Zielabweichungen des Instrumentes geringer als 1 mm waren, so dass Interventionen mit hoher Genauigkeit und Reproduzierbarkeit durchführbar wären. Das System implementiert benutzerfreundliche Oberflächen für die Interventionsplanung und für die Gerätesteuerung. Das vorliegende Dissertation stellt die Konzepte und Ergebnisse dieser neuen Biopsieeinrichtung vor und nimmt Bezug auf zahlreiche wissenschaftliche Untersuchungen, insbesondere im Hinblick auf die Anwendung von Materialien und Aktoren im MRT-Magnetfeld.
Abstract (eng):
Breast cancer is one of the most common cancer diseases which women suffer world wide. The incidence rate of breast cancer in Germany goes along with about 47.000 women per year, 18.000 fatal casualties were ascertained in the same period. The breast cancer diagnostic is based on clinical and different imaging methods, whereas Magnetic Resonance Imaging (MRI) is the most sensitive imaging modality in the detection of especially small lesions under 5 mm. Due to improvements of breast imaging - especially MRI - it has been predicted that by the year 2010 about 50% of newly diagnosed breast cancers will be less than 10 mm in size. However, to assure the image based breast cancer diagnosis, biopsies of tumor tissue are often necessary in order to avoid false specified results. With reference to the state of the art, it is still difficult to achieve sufficient accurate MRI-supported biopsies for tumor sizes of under 10 mm. To improve the MR-controlled diagnostic in respect of increasing the efficiency and precision of the biopsy method, a new apparatus for minimal invasive breast biopsies particularly for the use inside closed bore MRI-scanner was developed. This MR-compatible device is based on new concepts which meet the extremely high requirements on interventions in strong magnetic fields through special designs and kinematic concepts and the application of MR-compatible materials, actors and sensor systems. It is of a modular structure and consists mainly of an automated positioning unit and an integrated intervention tool. This new system makes it possible to do the breast interventions either from the cranial or the caudal position directly after tumor detecting with the use of a new double breast coil. A major advantage of this approach is the high accuracy and the possibility to realize image diagnostic and biopsy in one session. As the preclinical evaluation with a 1.5 T MRI-scanner showed, the deviation of the intervention device regarding instrument positioning to a located target was less than 1mm, so that interventions could be carried out precisely and reproducible. Furthermore there were no image interferences due to the additional materials in the MRI-isocenter. The system implements a user-interface for intervention planning on up-to-date MR images and device control. Besides the concepts and results of the new biopsy device, the present dissertation refers to numerous scientific investigations with a focus on material and actuator application in the magnetic field of a MRI-scanner.
Zugriffsstatistik: Die Daten für die Zugriffsstatistik der einzelnen Dokumente wurden aus den durch AWStats aggregierten Webserver-Logs erstellt. Sie beziehen sich auf den monatlichen Zugriff auf den Volltext sowie auf die Startseite. Die Zugriffsstatistik wird nicht standardisiert erfasst und kann maschinelle Zugriffe enthalten.
 
Bei Formatversionen eines Dokuments, die aus mehreren Dateien bestehen (insbesondere HTML), wird jeweils der monatlich höchste Zugriffswert auf eine der Dateien (Kapitel) des Dokuments angezeigt.
 
Um die detaillierten Zugriffszahlen zu sehen, fahren Sie bitte mit dem Mauszeiger über die einzelnen Balken des Diagramms.
Startseite: 2 Zugriffe HTML: 62 Zugriffe Startseite: 2 Zugriffe HTML: 56 Zugriffe PDF: 2 Zugriffe Startseite: 7 Zugriffe HTML: 50 Zugriffe PDF: 2 Zugriffe Startseite: 3 Zugriffe HTML: 96 Zugriffe PDF: 2 Zugriffe Startseite: 4 Zugriffe HTML: 85 Zugriffe PDF: 5 Zugriffe Startseite: 5 Zugriffe HTML: 104 Zugriffe PDF: 6 Zugriffe Startseite: 2 Zugriffe HTML: 91 Zugriffe PDF: 7 Zugriffe Startseite: 11 Zugriffe HTML: 100 Zugriffe PDF: 5 Zugriffe Startseite: 2 Zugriffe HTML: 94 Zugriffe PDF: 8 Zugriffe Startseite: 8 Zugriffe HTML: 81 Zugriffe PDF: 10 Zugriffe Startseite: 4 Zugriffe HTML: 68 Zugriffe PDF: 2 Zugriffe Startseite: 10 Zugriffe HTML: 83 Zugriffe PDF: 1 Zugriffe Startseite: 6 Zugriffe HTML: 81 Zugriffe PDF: 4 Zugriffe Startseite: 4 Zugriffe HTML: 99 Zugriffe PDF: 3 Zugriffe Startseite: 11 Zugriffe HTML: 107 Zugriffe PDF: 6 Zugriffe Startseite: 2 Zugriffe HTML: 72 Zugriffe HTML: 119 Zugriffe PDF: 27 Zugriffe HTML: 96 Zugriffe PDF: 27 Zugriffe Startseite: 2 Zugriffe HTML: 72 Zugriffe PDF: 22 Zugriffe Startseite: 3 Zugriffe HTML: 112 Zugriffe PDF: 16 Zugriffe Startseite: 1 Zugriffe HTML: 84 Zugriffe PDF: 17 Zugriffe Startseite: 4 Zugriffe HTML: 73 Zugriffe PDF: 13 Zugriffe Startseite: 3 Zugriffe HTML: 61 Zugriffe PDF: 17 Zugriffe Startseite: 4 Zugriffe HTML: 83 Zugriffe PDF: 24 Zugriffe Startseite: 6 Zugriffe HTML: 63 Zugriffe PDF: 14 Zugriffe Startseite: 9 Zugriffe HTML: 109 Zugriffe PDF: 23 Zugriffe Startseite: 8 Zugriffe HTML: 109 Zugriffe PDF: 24 Zugriffe Startseite: 6 Zugriffe HTML: 105 Zugriffe PDF: 10 Zugriffe Startseite: 9 Zugriffe HTML: 196 Zugriffe PDF: 19 Zugriffe Startseite: 5 Zugriffe HTML: 169 Zugriffe PDF: 20 Zugriffe Startseite: 6 Zugriffe HTML: 174 Zugriffe PDF: 33 Zugriffe Startseite: 9 Zugriffe HTML: 197 Zugriffe PDF: 37 Zugriffe Startseite: 6 Zugriffe HTML: 187 Zugriffe PDF: 42 Zugriffe Startseite: 11 Zugriffe HTML: 128 Zugriffe PDF: 47 Zugriffe
Jul
11
Aug
11
Sep
11
Oct
11
Nov
11
Dec
11
Feb
12
Apr
12
May
12
Jun
12
Jul
12
Aug
12
Sep
12
Oct
12
Nov
12
Dec
12
Jan
13
Feb
13
Mar
13
Apr
13
May
13
Jun
13
Jul
13
Aug
13
Sep
13
Oct
13
Nov
13
Dec
13
Jan
14
Feb
14
Mar
14
Apr
14
May
14
Jun
14
Monat Jul
11
Aug
11
Sep
11
Oct
11
Nov
11
Dec
11
Feb
12
Apr
12
May
12
Jun
12
Jul
12
Aug
12
Sep
12
Oct
12
Nov
12
Dec
12
Jan
13
Feb
13
Mar
13
Apr
13
May
13
Jun
13
Jul
13
Aug
13
Sep
13
Oct
13
Nov
13
Dec
13
Jan
14
Feb
14
Mar
14
Apr
14
May
14
Jun
14
Startseite 2 2 7 3 4 5 2 11 2 8 4 10 6 4 11 2     2 3 1 4 3 4 6 9 8 6 9 5 6 9 6 11
HTML 62 56 50 96 85 104 91 100 94 81 68 83 81 99 107 72 119 96 72 112 84 73 61 83 63 109 109 105 196 169 174 197 187 128
PDF   2 2 2 5 6 7 5 8 10 2 1 4 3 6   27 27 22 16 17 13 17 24 14 23 24 10 19 20 33 37 42 47

Gesamtzahl der Zugriffe seit Jul 2011:

  • Startseite – 175 (5.15 pro Monat)
  • HTML – 3466 (101.94 pro Monat)
  • PDF – 495 (15 pro Monat)
 
 
Generiert am 23.07.2014, 04:11:22