edoc-Server der Humboldt-Universität zu Berlin

Dissertation

Autor(en): Julia Ahlswede
Titel: Aspekte der Positionierung und Dosisapplikation in der stereotaktisch geführten intra- und extrakranialen Strahlentherapie
Gutachter: D. Georg; Th. Wendt; V. Budach
Erscheinungsdatum: 01.11.2005
Volltext: html (urn:nbn:de:kobv:11-10068911)
pdf (urn:nbn:de:kobv:11-10054708)
Fachgebiet(e): Medizin
Schlagwörter (ger): Stereotaxie, Radiotherapie, Radiochirurgie, Planvergleich, intra- und extra-kranielle Strahlentherapie
Schlagwörter (eng): Stereotactic, radiation therapy, radiation surgery, plan evaluation, intra- und extra cranial radiation therapy
Einrichtung: Humboldt-Universität zu Berlin, Medizinische Fakultät - Universitätsklinikum Charité
Zitationshinweis: Ahlswede, Julia: Aspekte der Positionierung und Dosisapplikation in der stereotaktisch geführten intra- und extrakranialen Strahlentherapie; Dissertation, Humboldt-Universität zu Berlin, Medizinische Fakultät - Universitätsklinikum Charité , publiziert am 01.11.2005, urn:nbn:de:kobv:11-10054708
Metadatenexport: Um den gesamten Metadatensatz im Endnote- oder Bibtex-Format zu speichern, klicken Sie bitte auf den entsprechenden Link. Endnote   Bibtex  
print on demand: Wenn Sie auf dieses Icon klicken, können Sie ein Druckexemplar dieser Publikation bestellen.

Abstract (ger):
Stereotaktische Strahlenchirurgie und -therapie (SRS/SRT) weisen sich durch sehr konformale und hochpräzise Dosisverteilungen aus. Im Kopfbereich ist SRS/SRT eine etablierte Behandlungsmethode. Um diese Technik in anderen Körperregionen anwenden zu können, wurden verschiedene Positionierungs- und Fixierungsmethoden, sowie der Einsatz von 9 verschiedene Bestrahlungstechniken untersucht. Es wurde auch die Genauigkeit von 2 Dosisalgorithmen evaluiert. Jeweils eine thermoplastische Maske für den Kopf- und den Kopf-Hals-Bereich, sowie ein Doppelvakuumsystem für extrakraniale Regionen wurden untersucht. Die Kopfmaske erreichte im Durchschnitt eine Genauigkeit von 1,8mm (Fehler 0,9mm), mit einem Oberkiefersupport auf 0,96mm +/- 0,25mm. Die Kopf-Hals-Maske zeigte mit 0,7mm +/- 0,4mm, dass ihre Verwendung in der SRS/SRT möglich ist. Für die Genauigkeit des Doppelvakuums wurde durchschnittlich 7,0mm +/-3,5mm ermittelt. Relativ zum Vakuumkissen wurde eine Genauigkeit von 1,6mm +/- 1,87mm gemessen. Evaluierungsmethoden waren IR-Marker, die mittels Zahnabdruck am Patienten fixiert wurden und fusionierte Wiederholungs-CTs, in denen die Verschiebung von Landmarken am Positionierungssystem und im Patienten vermessen wurden. Bei den Bestrahlungstechniken sind 3 Techniken durch gute Ergebnisse aufgefallen. Stehfeldtechnik, dynamischer Arc und IMRT zeigten mit einem 3mm-mMLC hohe Konformität und Homogenität auf. Die ersten beiden Techniken erreichten steile Dosisgradienten, wohingegen die IMRT bei komplexen Zielgebieten und nahen Risikostrukturen auffiel und immer die geforderte 90%-Umschließende erreichte. Die Verifizierung der Dosisalgorithmen erfolgte anhand von Filmen. 8 Pläne wurden jeweils auf einem Film in Isozentrumsebene abgebildet und ein Vergleich mit der berechneten Dosis von Clarkson- und Pencil-Beam-Algorithmus mit Hilfe der Gamma-Evaluation durchgeführt. Beide Algorithmen sind für die SRS/SRT geeignet, der Pencil-Beam-Algorithmus zusätzlich für die IMRT verwendbar.
Abstract (eng):
Stereotactic radiation surgery and therapy (SRS/SRT) are able to deliver conformal and precise dose distributions. For brain lesions SRS/SRT is a well-established technique. Its success increases interest to use it in other areas of the body. For this, evaluation of different patient positioning and treatment techniques, as well as dose algorithms have been performed. As patient fixation and positioning systems, 2 thermoplastic masks were evaluated for lesions located in the brain and the head and neck. In addition a double vacuum system for extra cranial treatments was used. The precision for the head mask was on average 1,8mm +/- 0,9mm, with an upper jaw support 0,9mm +/- 0,25mm. The head and neck mask realized a reproducibility of 0,7mm +/- 0,4mm and proved its use for SRS/SRT. For extra cranial positioning an average lesion misplacement of 7,0 mm +/-3,5 mm was measured. Relative to the vacuum cushion the accuracy was measured to be 1,6mm +/- 1,9mm. Infrared reflecting marker fixed precisely (+/- 0,6mm) with a dental impression and repeated CTs fused and landmark evaluated were successfully used to evaluate the patient fixation and positioning devices. 3 out of 9 treatment techniques had outstanding results. Static beams, dynamic arcs and IMRT all performed with a 3mm-mMLC showed a high conformity and homogeneity. The first two showed steep dose gradients and the later coped best with complex target shapes, close-by risk organs, and achieving 90% dose coverage. Verification of 2 algorithms was established with film. 8 plans were irradiated on film at isocenter and compared to calculations with Clarkson and pencil beam algorithm. Final evaluation was done using Gamma evaluation. Both algorithms showed their ability for SRS/SRT. The pencil beam algorithm is also capable of calculating IMRT plans. Summing the results the finding show that the use of some of the SRS-SRT techniques used for the head may be transferred for the use in extra cranial areas.
Zugriffsstatistik: Die Daten für die Zugriffsstatistik der einzelnen Dokumente wurden aus den durch AWStats aggregierten Webserver-Logs erstellt. Sie beziehen sich auf den monatlichen Zugriff auf den Volltext sowie auf die Startseite. Die Zugriffsstatistik wird nicht standardisiert erfasst und kann maschinelle Zugriffe enthalten.
 
Bei Formatversionen eines Dokuments, die aus mehreren Dateien bestehen (insbesondere HTML), wird jeweils der monatlich höchste Zugriffswert auf eine der Dateien (Kapitel) des Dokuments angezeigt.
 
Um die detaillierten Zugriffszahlen zu sehen, fahren Sie bitte mit dem Mauszeiger über die einzelnen Balken des Diagramms.
Startseite: 15 Zugriffe HTML: 17 Zugriffe PDF: 67 Zugriffe Startseite: 17 Zugriffe HTML: 29 Zugriffe PDF: 92 Zugriffe Startseite: 2 Zugriffe HTML: 17 Zugriffe PDF: 33 Zugriffe Startseite: 16 Zugriffe HTML: 23 Zugriffe PDF: 37 Zugriffe Startseite: 16 Zugriffe HTML: 12 Zugriffe PDF: 36 Zugriffe Startseite: 28 Zugriffe HTML: 19 Zugriffe PDF: 34 Zugriffe Startseite: 26 Zugriffe HTML: 28 Zugriffe PDF: 40 Zugriffe Startseite: 15 Zugriffe HTML: 30 Zugriffe PDF: 33 Zugriffe Startseite: 16 Zugriffe HTML: 45 Zugriffe PDF: 52 Zugriffe Startseite: 22 Zugriffe HTML: 50 Zugriffe PDF: 1 Zugriffe Startseite: 22 Zugriffe HTML: 45 Zugriffe PDF: 19 Zugriffe Startseite: 12 Zugriffe HTML: 39 Zugriffe PDF: 32 Zugriffe Startseite: 29 Zugriffe HTML: 49 Zugriffe PDF: 44 Zugriffe Startseite: 39 Zugriffe HTML: 32 Zugriffe PDF: 1 Zugriffe Startseite: 31 Zugriffe HTML: 48 Zugriffe PDF: 107 Zugriffe Startseite: 25 Zugriffe HTML: 43 Zugriffe PDF: 30 Zugriffe Startseite: 32 Zugriffe HTML: 18 Zugriffe PDF: 39 Zugriffe
Jan
16
Feb
16
Mar
16
Apr
16
May
16
Jun
16
Jul
16
Aug
16
Sep
16
Oct
16
Nov
16
Dec
16
Jan
17
Feb
17
Mar
17
Apr
17
May
17
Monat Jan
16
Feb
16
Mar
16
Apr
16
May
16
Jun
16
Jul
16
Aug
16
Sep
16
Oct
16
Nov
16
Dec
16
Jan
17
Feb
17
Mar
17
Apr
17
May
17
Startseite 15 17 2 16 16 28 26 15 16 22 22 12 29 39 31 25 32
HTML 17 29 17 23 12 19 28 30 45 50 45 39 49 32 48 43 18
PDF 67 92 33 37 36 34 40 33 52 1 19 32 44 1 107 30 39

Gesamtzahl der Zugriffe seit Jan 2016:

  • Startseite – 363 (21.35 pro Monat)
  • HTML – 544 (32 pro Monat)
  • PDF – 697 (41 pro Monat)
 
 
Generiert am 24.06.2017, 07:26:06