edoc-Server der Humboldt-Universität zu Berlin

Dissertation

Autor(en): Torsten Schmidt
Titel: Identifizierung und Untersuchung pharmazeutischer Gläser durch Laser-Ablation-ICP-MS
Gutachter: Adolf Zschunke; P. Surmann
Erscheinungsdatum: 26.11.2001
Volltext: html (urn:nbn:de:kobv:11-10037692)
pdf (urn:nbn:de:kobv:11-10015792)
Fachgebiet(e): Chemie
Schlagwörter (ger): Laser Ablation, ICP-MS, Pharmazeutisches Glas, chemische Glaszusammensetzung, Lineare Diskriminanzanalyse
Schlagwörter (eng): laser ablation, ICP-MS, pharmaceutical glass, chemical composition of glass, linear discriminant analysis
Einrichtung: Humboldt-Universität zu Berlin, Mathematisch-Naturwissenschaftliche Fakultät I
Zitationshinweis: Schmidt, Torsten: Identifizierung und Untersuchung pharmazeutischer Gläser durch Laser-Ablation-ICP-MS; Dissertation, Humboldt-Universität zu Berlin, Mathematisch-Naturwissenschaftliche Fakultät I , publiziert am 26.11.2001, urn:nbn:de:kobv:11-10015792
Metadatenexport: Um den gesamten Metadatensatz im Endnote- oder Bibtex-Format zu speichern, klicken Sie bitte auf den entsprechenden Link. Endnote   Bibtex  
print on demand: Wenn Sie auf dieses Icon klicken, können Sie ein Druckexemplar dieser Publikation bestellen.
Diese Seite taggen: Diese Icons führen auf so genannte Social-Bookmark-Systeme, auf denen Sie Lesezeichen anlegen, persönliche Tags vergeben und Lesezeichen anderer Nutzer ansehen können.
  • connotea
  • del.icio.us
  • Furl
  • RawSugar

Abstract (ger):
Die chemische Zusammensetzung pharmazeutisch verwendeter Gläser (Ampullen, Infusionsglas, Fertigspritzenbehältnisse) wurde mit Laser-Ablation-ICP-Massenspektrometrie (LA-ICP-MS) untersucht. Dazu kam ein Nd:YAG-Laser mit einer Frequenz von 10 Hz im q-switch mode mit der Grundwellenlänge sowie der 4. Harmonischen (1064 und 266 nm) zum Einsatz. Ziel war die Identifizierung verschiedener Arten pharmazeutisch eingesetzter Gläser. Folgende Isotope wurden zur Charakterisierung bestimmt: 7Li, 11B, 23Na, 24Mg, 27Al, 28Si, 29Si, 30Si, 39K, 42Ca, 47Ti, 57Fe, 90Zr, 121Sb, 137Ba. Die quantitativen Ergebnisse zeigten relative Standardabweichungen von 1.8 % bis 8.0 %. Die Normierung der Daten erfolgte unter Bezug auf 29Si. Mit Referenzmaterial verschiedener Zusammensetzung (Natron-Kalk-Glas, Borosilikatglas und Bleiglas) wurden externe Mehrpunktkalibrationen erstellt. Für alle gemessenen Isotope konnten lineare Kalibrierfunktionen festgestellt werden. Die Richtigkeit des Verfahrens wurde durch Aufschluß des Standardmaterials wie auch der untersuchten Proben mit Flußsäure/Salpetersäure und Messung der Aufschlußlösungen nach externer Kalibration durch Multielement-Standards gezeigt. Aufschluß- und Laserablation-Ergebnisse zeigten gute Übereinstimmung und wichen um bis zu 8 % voneinander ab. Zur Prüfung repräsentativer Ablation der Proben wurden die Isotopenverhältnisse bestimmt. Auch hier zeigte sich eine ausreichende Übereinstimmung mit den theoretischen Werten. Weiterhin wurden Präzision, Empfindlichkeit, Selektivität, Nachweisgrenze, Bestimmungsgrenze und Robustheit des Verfahrens bestimmt. Im Unterschied zu den Ergebnissen unter der Grundwellenlänge führte die Verwendung der Laserwellenlänge 266 nm zu keinen signifikanten Verbesserungen der Resultate. Die Aufnahme transienter Signale sollte zur Erkennung von Elementverteilungen in Glasoberflächen dienen. Am Beispiel eines Natron-Kalk-Glases wurden in einzelnen Schichten verschiedene Elementkonzentrationen festgestellt. Weiterhin konnten mit dieser Technik Glasampullen erkannt werden, deren Oberflächen durch ein Silikonisierungsverfahren vergütet waren. Zum Abschluß der Untersuchungen wurde versucht, auf Grundlage der unnormierten Intensitätsdaten der LA-Messungen Gläser zu klassifizieren. Hierzu wurde die lineare Diskriminanzanalyse eingesetzt, mit deren Hilfe nach Variablenreduktion (8 von 13 Isotopen) alle eingesetzten Glasarten korrekt identifiziert werden konnten. Durch das entwickelte und validierte LA-ICP-MS-Verfahren steht eine leistungsfähige Technik zur quantitativen Untersuchung der chemischen Zusammensetzung von Gläsern sowie zur Identifizierung der jeweiligen Glassorte zur Verfügung.
Abstract (eng):
The chemical composition of pharmaceutical glasses (ampoules, infusion bottles, plunger) has been determined by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). A Nd:YAG laser with 10 Hz repetition rate in the q-switch mode at its fundamental wavelength and its 4th harmonic (1064 and 266 nm) was used to identify common types of pharmaceutical glasses. The following isotopes were used for measurements: 7Li, 11B, 23Na, 24Mg, 27Al, 28Si, 29Si, 30Si, 39K, 42Ca, 47Ti, 57Fe, 90Zr, 121Sb, 137Ba. Relative standard deviations between 1.8 % and 8.0 % of the quantitative results were obtained. 29Si was used as internal standard. Standard reference materials (soda-lime-, lead- and borosilicate glasses) were used for external calibration of laser sampling. Linear calibration functions for each isotope were found. The accuracy was determined by digestion of all samples and standard materials in a two-step-procedure by nitric/fluoric acid, measurement and external calibration by ICP-MS with multi-elemental standard solutions. Digestion and laser ablation results agreed within 8 % with the certified values. The proof of representative ablation was given by sufficient agreement of intensity ratios of most isotopes with the corresponding theoretical values. Further precision, sensititivity, selectivity, limit of detection, limit of quantitation and robustness were determined. In contrast to the fundamental wavelength the laserablation technique with 266 nm showed no significant improvement in the quality of the results. By measuring transient signals element concentrations of surface layers should be detected. Differing concentrations could be determined in soda-lime-glass samples. Also different surface-treated borosilicate-glass ampoules were examined by this method. Silicon-treated glass surfaces could be identified. Finally raw data of LA measurements were used for applying linear discriminant analysis. After reduction of the used variables (8 of 13 isotopes) all types of glasses could be distinguished only by their intensity data of LA measurements. The developed LA-ICP-MS method is a powerful technique to distinguish different types of pharmaceutical glasses and to examine their chemical composition.
Zugriffsstatistik: Die Daten für die Zugriffsstatistik der einzelnen Dokumente wurden aus den durch AWStats aggregierten Webserver-Logs erstellt. Sie beziehen sich auf den monatlichen Zugriff auf den Volltext sowie auf die Startseite. Die Zugriffsstatistik wird nicht standardisiert erfasst und kann maschinelle Zugriffe enthalten.
 
Bei Formatversionen eines Dokuments, die aus mehreren Dateien bestehen (insbesondere HTML), wird jeweils der monatlich höchste Zugriffswert auf eine der Dateien (Kapitel) des Dokuments angezeigt.
 
Um die detaillierten Zugriffszahlen zu sehen, fahren Sie bitte mit dem Mauszeiger über die einzelnen Balken des Diagramms.
Startseite: 6 Zugriffe HTML: 23 Zugriffe PDF: 6 Zugriffe HTML: 31 Zugriffe PDF: 12 Zugriffe Startseite: 3 Zugriffe HTML: 42 Zugriffe PDF: 15 Zugriffe Startseite: 2 Zugriffe HTML: 44 Zugriffe PDF: 14 Zugriffe Startseite: 2 Zugriffe HTML: 43 Zugriffe PDF: 26 Zugriffe HTML: 41 Zugriffe PDF: 16 Zugriffe Startseite: 1 Zugriffe HTML: 49 Zugriffe PDF: 34 Zugriffe Startseite: 11 Zugriffe HTML: 31 Zugriffe PDF: 37 Zugriffe HTML: 44 Zugriffe PDF: 34 Zugriffe Startseite: 4 Zugriffe HTML: 38 Zugriffe PDF: 31 Zugriffe Startseite: 5 Zugriffe HTML: 57 Zugriffe PDF: 49 Zugriffe HTML: 41 Zugriffe PDF: 40 Zugriffe Startseite: 1 Zugriffe HTML: 44 Zugriffe PDF: 37 Zugriffe Startseite: 1 Zugriffe HTML: 41 Zugriffe PDF: 45 Zugriffe Startseite: 8 Zugriffe HTML: 43 Zugriffe PDF: 40 Zugriffe Startseite: 3 Zugriffe HTML: 40 Zugriffe PDF: 32 Zugriffe Startseite: 4 Zugriffe HTML: 49 Zugriffe PDF: 100 Zugriffe Startseite: 3 Zugriffe HTML: 35 Zugriffe PDF: 90 Zugriffe Startseite: 1 Zugriffe HTML: 42 Zugriffe PDF: 82 Zugriffe Startseite: 4 Zugriffe HTML: 37 Zugriffe PDF: 98 Zugriffe Startseite: 2 Zugriffe HTML: 37 Zugriffe PDF: 97 Zugriffe Startseite: 1 Zugriffe HTML: 43 Zugriffe PDF: 103 Zugriffe Startseite: 3 Zugriffe HTML: 42 Zugriffe PDF: 94 Zugriffe Startseite: 6 Zugriffe HTML: 46 Zugriffe PDF: 90 Zugriffe Startseite: 5 Zugriffe HTML: 28 Zugriffe PDF: 70 Zugriffe Startseite: 7 Zugriffe HTML: 34 Zugriffe PDF: 155 Zugriffe Startseite: 16 Zugriffe HTML: 53 Zugriffe PDF: 112 Zugriffe Startseite: 23 Zugriffe HTML: 31 Zugriffe PDF: 84 Zugriffe Startseite: 20 Zugriffe HTML: 66 Zugriffe PDF: 137 Zugriffe Startseite: 21 Zugriffe HTML: 62 Zugriffe PDF: 118 Zugriffe Startseite: 23 Zugriffe HTML: 63 Zugriffe PDF: 130 Zugriffe
Jul
11
Aug
11
Sep
11
Oct
11
Nov
11
Dec
11
Feb
12
Apr
12
May
12
Jun
12
Jul
12
Aug
12
Sep
12
Oct
12
Nov
12
Dec
12
Jan
13
Feb
13
Mar
13
Apr
13
May
13
Jun
13
Jul
13
Aug
13
Sep
13
Oct
13
Nov
13
Dec
13
Jan
14
Feb
14
Mar
14
Monat Jul
11
Aug
11
Sep
11
Oct
11
Nov
11
Dec
11
Feb
12
Apr
12
May
12
Jun
12
Jul
12
Aug
12
Sep
12
Oct
12
Nov
12
Dec
12
Jan
13
Feb
13
Mar
13
Apr
13
May
13
Jun
13
Jul
13
Aug
13
Sep
13
Oct
13
Nov
13
Dec
13
Jan
14
Feb
14
Mar
14
Startseite 6   3 2 2   1 11   4 5   1 1 8 3 4 3 1 4 2 1 3 6 5 7 16 23 20 21 23
HTML 23 31 42 44 43 41 49 31 44 38 57 41 44 41 43 40 49 35 42 37 37 43 42 46 28 34 53 31 66 62 63
PDF 6 12 15 14 26 16 34 37 34 31 49 40 37 45 40 32 100 90 82 98 97 103 94 90 70 155 112 84 137 118 130

Gesamtzahl der Zugriffe seit Jul 2011:

  • Startseite – 186 (6 pro Monat)
  • HTML – 1320 (42.58 pro Monat)
  • PDF – 2028 (65.42 pro Monat)
 
 
Generiert am 24.04.2014, 08:24:24