edoc-Server der Humboldt-Universität zu Berlin

Habilitationsschrift

Autor(en): Arne-Jörn Lemke
Titel: Integration magnetresonanztomographischer und computertomographischer Daten mit isotropen Voxeln in die Protonenbestrahlungsplanung bei okularen Tumoren
Erscheinungsdatum: 12.11.2001
Volltext: html (urn:nbn:de:kobv:11-10070278)
pdf (urn:nbn:de:kobv:11-10022902)
xml (urn:nbn:de:kobv:11-10070286)
Fachgebiet(e): Medizin
Schlagwörter (ger): Computertomographie, Magnetresonanztomographie, Aderhautmelanom, Bestrahlungsplanung, Protonentherapie, isotrope Voxel, Phantomuntersuchungen
Schlagwörter (eng): computed tomography, uveal melanoma, magnetic resonance tomography, radiation planning, proton therapy, isotropic voxels, phantom examinations
Einrichtung: Humboldt-Universität zu Berlin, Medizinische Fakultät - Universitätsklinikum Charité
Zitationshinweis: Lemke, Arne-Jörn: Integration magnetresonanztomographischer und computertomographischer Daten mit isotropen Voxeln in die Protonenbestrahlungsplanung bei okularen Tumoren; Habilitationsschrift, Humboldt-Universität zu Berlin, Medizinische Fakultät - Universitätsklinikum Charité , publiziert am 12.11.2001, urn:nbn:de:kobv:11-10070286
Metadatenexport: Um den gesamten Metadatensatz im Endnote- oder Bibtex-Format zu speichern, klicken Sie bitte auf den entsprechenden Link. Endnote   Bibtex  
print on demand: Wenn Sie auf dieses Icon klicken, können Sie ein Druckexemplar dieser Publikation bestellen.
Diese Seite taggen: Diese Icons führen auf so genannte Social-Bookmark-Systeme, auf denen Sie Lesezeichen anlegen, persönliche Tags vergeben und Lesezeichen anderer Nutzer ansehen können.
  • connotea
  • del.icio.us
  • Furl
  • RawSugar

Abstract (ger):
Die Bestrahlungstherapie von Aderhautmelanomen mit der Protonentherapie stellt ein sehr präzises Behandlungsverfahren dar, welches hohe Ansprüche an die zugrundliegende Bildgebung stellt. Die Magnetresonanztomographie (MRT) und Computertomographie (CT) scheinen prinzipiell in der Lage, mit geeigneten Oberflächenspulen bzw. angepaßter Untersuchungstechnik diese Ansprüche zu erfüllen. Ziel der Arbeit ist die Bereitstellung und Überprüfung eines bildgebenden Systems, das einerseits die diagnostischen und differentialdiagnostischen Aufgaben für die Differenzierung und das Staging von Aderhautmelanomen erfüllt und andererseits als Grundlage der Bestrahlungsplanung dienen kann. Erstrebenswert ist dabei die Erstellung von Schnittbildern bestehend aus isotropen Voxeln, d.h. Voxeln mit identischer Kantenlänge, mit der Magnetresonanztomographie (MRT) und der Computertomographie (CT). Zur Differenzierung der unterschiedlichen Tumorentitäten wurden verschiedene Untersuchungen mit zum Teil großen Patientenkollektiven durchgeführt und histologisch und klinisch korreliert bzw. verifiziert. Dabei konnte das MR-morphologische Erscheinungsbild der relevanten Erkrankungen studiert werden. Die Genauigkeit der MR-gestützten Tumorvolumetrie wurde in vitro im Tierversuch und in vivo am Patientenauge überprüft. Zur Überprüfung der Genauigkeit der MR-Bildgebung mit isotropen Voxeln wurden unterschiedliche Spulen getestet und verschiedene Phantomuntersuchungen durchgeführt. Entsprechend wurde auch die CT evaluiert. Mit der digitalen Bildfusion wurden die MRT- und die CT-Daten in einen gemeinsamen Datensatz überführt, der sowohl zur Bestimmung der Genauigkeit beider Verfashren als auch als Basis zur Bestrahlungsplanung verwendet werden konnte. Mit einer optimierten Untersuchungstechnik konnten Schnittbilder auf der Basis von CT und MRT zur Verfügung gestellt werden, die eine präzise Planung der Protonenbestrahlung beim Aderhautmelanom ermöglichen.
Abstract (eng):
The radiation therapy of uveal melanomas using proton therapy is a very precise therapy procedure, that makes high demands on the underlying imaging modalities. In general magnetic resonance imaging (MRI) and computed tomography (CT) have the potential to fulfill these criteria using suited surface coils and optimized imaging techniques, respectively. Purpose of the investigations was the preparation and evaluation of an imaging system, that allows diagnosis and differetial diagnosis of uveal melanomas including staging on the one hand. On the other hand it should be the base for high precision radiation therapy planning. The preparation of images with isotropic voxels, i.e. the edges of the voxels have identical size, is desirable with both magnetic resonance imaging (MRI) and computed tomography (CT). Several examinations on large patient groups were performed for the differentiation of different tumor entities and compared with clinical and histopathological outcome. The precision of the MR-based tumor volumetry was evaluated with animal studies in vitro and patient eyes in vivo. The MR-imaging with isotropic voxels was evaluated using several surface coils and phantom examinations. Comparable examinations were performed regarding CT. Digital image fusion of CT and MRI data sets was used to evaluate the precision of both modalities and for planning of radiation therapy. Using optimized examination techniques both CT and especially MRI are suitable for a precise proton therapy planning of uveal melanoma.
Zugriffsstatistik: Die Daten für die Zugriffsstatistik der einzelnen Dokumente wurden aus den durch AWStats aggregierten Webserver-Logs erstellt. Sie beziehen sich auf den monatlichen Zugriff auf den Volltext sowie auf die Startseite. Die Zugriffsstatistik wird nicht standardisiert erfasst und kann maschinelle Zugriffe enthalten.
 
Bei Formatversionen eines Dokuments, die aus mehreren Dateien bestehen (insbesondere HTML), wird jeweils der monatlich höchste Zugriffswert auf eine der Dateien (Kapitel) des Dokuments angezeigt.
 
Um die detaillierten Zugriffszahlen zu sehen, fahren Sie bitte mit dem Mauszeiger über die einzelnen Balken des Diagramms.
Startseite: 9 ZugriffeHTML: 108 ZugriffePDF: 5 ZugriffeStartseite: 13 ZugriffeHTML: 99 ZugriffeStartseite: 10 ZugriffeHTML: 91 ZugriffePDF: 1 ZugriffeStartseite: 4 ZugriffeHTML: 62 ZugriffePDF: 2 ZugriffeStartseite: 5 ZugriffeHTML: 68 ZugriffePDF: 1 ZugriffeStartseite: 2 ZugriffeHTML: 63 ZugriffePDF: 1 ZugriffeStartseite: 6 ZugriffeHTML: 92 ZugriffePDF: 6 ZugriffeStartseite: 7 ZugriffeHTML: 87 ZugriffePDF: 5 ZugriffeStartseite: 9 ZugriffeHTML: 120 ZugriffePDF: 4 ZugriffeStartseite: 6 ZugriffeHTML: 89 ZugriffePDF: 2 ZugriffeStartseite: 3 ZugriffeHTML: 107 ZugriffePDF: 6 ZugriffeStartseite: 6 ZugriffeHTML: 94 ZugriffePDF: 3 ZugriffeStartseite: 8 ZugriffeHTML: 118 ZugriffePDF: 6 ZugriffeStartseite: 4 ZugriffeHTML: 73 ZugriffePDF: 8 ZugriffeStartseite: 1 ZugriffeHTML: 77 ZugriffeStartseite: 3 ZugriffeHTML: 84 ZugriffePDF: 2 ZugriffeStartseite: 6 ZugriffeHTML: 98 ZugriffePDF: 4 ZugriffeStartseite: 6 ZugriffeHTML: 115 ZugriffePDF: 3 ZugriffeStartseite: 2 ZugriffeHTML: 80 ZugriffePDF: 6 ZugriffeHTML: 98 ZugriffePDF: 24 ZugriffeStartseite: 3 ZugriffeHTML: 77 ZugriffePDF: 24 Zugriffe
May
11
Jun
11
Jul
11
Aug
11
Sep
11
Oct
11
Nov
11
Dec
11
Jan
12
Feb
12
Apr
12
May
12
Jun
12
Jul
12
Aug
12
Sep
12
Oct
12
Nov
12
Dec
12
Jan
13
Apr
13

MonatMay
11
Jun
11
Jul
11
Aug
11
Sep
11
Oct
11
Nov
11
Dec
11
Jan
12
Feb
12
Apr
12
May
12
Jun
12
Jul
12
Aug
12
Sep
12
Oct
12
Nov
12
Dec
12
Jan
13
Apr
13
Startseite913104526796368413662 3
HTML10899916268639287120891079411873778498115809877
PDF5 121165426368 24362424

Gesamtzahl der Zugriffe seit May 2011:

  • Startseite – 113 (5.38 pro Monat)
  • HTML – 1900 (90.48 pro Monat)
  • PDF – 113 (5.38 pro Monat)
  •  
 
Generiert am 25.05.2013, 16:51:06