Titel: Implantation ballon-expandierbarer Stents zur Therapie von Gefäßstenosen im Kindesalter – Indikationen, Nachsorge und Limitationen
Gutachter: A. Lindinger; A. Schmaltz
Erscheinungsdatum: 02.07.2002
Volltext: html (urn:nbn:de:kobv:11-10023596)
pdf (urn:nbn:de:kobv:11-10023605)
Fachgebiet(e): Medizin
Schlagwörter (ger): angeborene Herzfehler, interventionelle Kardiologie, Ballondilatation, Stent
Schlagwörter (eng): congenital heart disease, interventional cardiology, balloon dilation, Stent
Einrichtung: Humboldt-Universität zu Berlin, Medizinische Fakultät - Universitätsklinikum Charité
Zitationshinweis: Schneider, Martin Benno Erik: Implantation ballon-expandierbarer Stents zur Therapie von Gefäßstenosen im Kindesalter – Indikationen, Nachsorge und Limitationen; Habilitationsschrift, Humboldt-Universität zu Berlin, Medizinische Fakultät - Universitätsklinikum Charité , publiziert am 02.07.2002, urn:nbn:de:kobv:11-10023619
Metadatenexport: Um den gesamten Metadatensatz im Endnote- oder Bibtex-Format zu speichern, klicken Sie bitte auf den entsprechenden Link. Endnote   Bibtex  
print on demand: Wenn Sie auf dieses Icon klicken, können Sie ein Druckexemplar dieser Publikation bestellen.
Diese Seite taggen: Diese Icons führen auf so genannte Social-Bookmark-Systeme, auf denen Sie Lesezeichen anlegen, persönliche Tags vergeben und Lesezeichen anderer Nutzer ansehen können.
  • connotea
  • del.icio.us
  • Furl
  • RawSugar

Abstract (ger):
In der vorliegenden Arbeit werden die Ergebnisse von Stent Implantationen bei Kindern mit angeborenen Herzfehlern an der Humboldt Universität zu Berlin, Charité vorgestellt. Zwischen 1994 und 2001 wurden bei 103 Patienten 146/149 Stents erfolgreich in 115 Gefäßstenosen oder Ductus arteriosus implantiert. Das Alter der Patienten bei der Implantation lag zwischen einem Tag und 34 Jahren (ein erwachsener Patient), im Mittel 4 Jahre, Median 1,1 Jahre; das Körpergewicht lag zwischen 1,75 kg und 75 kg, im Mittel 14,4 kg bei einem Median von 7,5 kg. Von den 149 Stents wurden 39,5% in periphere Pulmonalarterienstenosen, 17,5% in Aortenisthmusstenosen, 28,5% in den Ductus arteriosus, 8,5% in Systemvenenstenosen und 6% in Pulmonalvenenstenosen. 40% der 146 erfolgreich implantierten Stents wurden palliativ, 60% kurativ implantiert. Während eines Nachbeobachtungszeitraumes von einem Monat bis 7,5 Jahren, im Mittel 2,14 Jahren, wurden 60 der implantierten Stents insgesamt 79 mal redilatiert. 15 dieser Stents zweimal und 4 dreimal. Der häufigste Grund für eine Redilatation war das Körperwachstum der Patienten (58%). In-Stent Restenosen aufgrund von Intima-Proliferation führten in 25,5% zu einer Redilatation, die übrigen 16,5% Restenosen wurden durch Kompression von außen verursacht. Bei der vorliegenden Studie zeigte sich, dass die Stent-Implantation nicht nur eine effektive Methode zur Behandlung von Gefäßstenosen bei Patienten mit angeborenen Herzfehlern ist. Vielmehr gilt sie bei dem vorgestellten Patientengut als: 1. Vorbereitung, Erleichterung oder Ermöglichung von korrigierenden Operationen bei Neugeborenen durch palliativen Stent Einsatz in den Ductus arteriosus, Aortenisthmusstenosen oder in interventionell eröffnete rechtsventrikuläre Ausflußtrakte; 2. Vermeidung komplexer chirurgischer Eingriffe durch Stent Implantationen in native Aortenisthmusstenosen oder in den Ductus arteriosus bei Patienten mit kritischer Pulmonalstenose oder- atresie mit intaktem Ventrikelseptum; 3. Verbesserung post-operativer Ergebnisse und damit Verbesserung der langfristigen Prognose durch Beseitigung post-operativer Restenosen, zum Beispiel peripherer Pulmonalstenosen nach operativer Korrektur einer Fallotschen Tetralogie. Darüber hinaus lassen sich mit Hilfe von Stents komplexe chirurgisch/interventionelle Therapiestrategien, zum Beispiel dem Etablieren einer Fontanzirkulation, verwirklichen. Da in den meisten Fällen ein lebenslanger Verbleib der Stents geplant war wurden ausschließlich ballonexpandierbare Stents implantiert. Diese können, dem Alter und dem Körperwachstum der Patienten entsprechend durch Redilatation angepaßt werden. Diese limitierten Langzeit-Ergebnisse erscheinen diesbezüglich vielversprechend. Dagegen sind die Ursachen der In-Stent Restenosen aufgrund von Intima-Proliferation, die bei einigen Kindern gefunden wurden, noch nicht verstanden und bedürfen weiterer Untersuchungen. Eine Limitation der vorgestellten Methode besteht in der Stent-Technologie. Derzeit stehen keine Stents zur Verfügung, die im Neugeborenenalter implantiert werden können und bis zum Abschluß des Größenwachstums der Patienten eine gefäßstützende Funktion gewährleisten. Neue Stent-Technologien sind daher für den kurativen Einsatz bei Neugeborenen und kleinen Säuglingen erforderlich und werden in dieser Arbeit im Tiermodel vorgestellt. Zwei unterschiedliche neu Stents, die von zwei unabhängigen Herstellern entwickelt wurden, können durch eine Miniaturisierung der Einführungssysteme im Neugeborenenalter eingesetzt werden und ermöglichen eine Erweiterung der gestenteten Gefäßdurchmesser von minimal 4 Millimeter auf über 20 Millimeter. Weitere chronische Untersuchungen im Tiermodel sind notwendig bevor diese neuen Stent-Technologien in die klinische Erprobung bei Neugeborenen mit angeborenen Herzfehlern eingeführt werden können.
Abstract (eng):
This study reports on stent implantation in paediatric patients with congenital heart disease at the department of paediatric cardiology, Humboldt university of Berlin, Charité. Between 1994 and 2001 146/149 stents were successfully implanted in 115 lesions or arterial ducts of 103 patients. The age of the patients ranged between 1 day and 34 years (one adult patient), mean 4 years, median 1.1 years; the bodyweight was measured between 1.75 kg and 75 kg, mean 14.4 kg, median 7.5 kg. The stent were implanted into different lesions: 39.5% in peripheral pulmonary artery stenoses, 17.5% in coarctation, 28.5% in the arterial duct, 8.5% in systemic vein stenoses and 6% in pulmonary vein stenoses. The implantations were performed for palliativ reasons in 40% or as a definite treatment in 60%. During a follow up period between 1 months and 7.5 years, mean 2.14 years 79 repeat dilations were performed on 60 stents, 15 stents twice and 4 stents three times. The most common reason for repeat intervention were dilation according to patients growth (58%). In-stent restenoses due to intimal hyperplasia were noted in 25.5% and 16.5% restenoses occurred due to compression from surrounding structures. The results of this study demonstrated stent-implantation not only as an effective method for treatment of vessel stenosis in young patients with congenital heart diseases. In addition 1. palliative stenting of the arterial duct, critical coarctation or right ventricular outflow tract obstruction in neonates improves surgical outcome or increases operability. 2. stent implantation can be an attractive alternative to complex surgery i.e. the establishment of Fontan circulation as part of a combined surgical/interventional concept 3. postoperative stenting of restenosis improves surgical results and reduces mortality and morbidity by reduction of the individual number of surgical procedures. Balloon expandable stents were used exclusively as the vast majority were considered to treat vessel stenosis for a lifelong period. The limited experiences on long-term follow-up are encouraging concerning the possibility of repeat dilation according to patients growth. However, the mechanisms of in-stent restenosis are not fully understand. For long-term treatment of vessel stenosis in neonates and small infants the conventional stent technology was found as a major limitation. New stent-designs are necessary. The report encloses two different new stent-technologies in animal studies. Miniaturised stents and delivery systems developed by two different companies are demonstrated. An additional advantage of the new stent designs is the broad variability of the stent diameters. After the initial implantation with a minimum diameter of 4 millimetres those stents can be dilated to a maximum diameter of more than 20 millimetres. Further investigations are necessary to demonstrate the efficacy of the new stent designs in different lesions of human neonates.
Zugriffsstatistik: Die Daten für die Zugriffsstatistik der einzelnen Dokumente wurden aus den durch AWStats aggregierten Webserver-Logs erstellt. Sie beziehen sich auf den monatlichen Zugriff auf den Volltext sowie auf die Startseite. Die Zugriffsstatistik wird nicht standardisiert erfasst und kann maschinelle Zugriffe enthalten.
 
Bei Formatversionen eines Dokuments, die aus mehreren Dateien bestehen (insbesondere HTML), wird jeweils der monatlich höchste Zugriffswert auf eine der Dateien (Kapitel) des Dokuments angezeigt.
 
Um die detaillierten Zugriffszahlen zu sehen, fahren Sie bitte mit dem Mauszeiger über die einzelnen Balken des Diagramms.
Startseite: 2 Zugriffe HTML: 22 Zugriffe PDF: 27 Zugriffe HTML: 21 Zugriffe PDF: 30 Zugriffe HTML: 23 Zugriffe PDF: 39 Zugriffe Startseite: 2 Zugriffe HTML: 30 Zugriffe PDF: 31 Zugriffe Startseite: 1 Zugriffe HTML: 29 Zugriffe PDF: 30 Zugriffe HTML: 38 Zugriffe PDF: 26 Zugriffe Startseite: 12 Zugriffe HTML: 45 Zugriffe PDF: 52 Zugriffe Startseite: 13 Zugriffe HTML: 56 Zugriffe PDF: 39 Zugriffe Startseite: 2 Zugriffe HTML: 35 Zugriffe PDF: 42 Zugriffe Startseite: 3 Zugriffe HTML: 43 Zugriffe PDF: 28 Zugriffe Startseite: 4 Zugriffe HTML: 34 Zugriffe PDF: 58 Zugriffe Startseite: 1 Zugriffe HTML: 40 Zugriffe PDF: 46 Zugriffe Startseite: 1 Zugriffe HTML: 26 Zugriffe PDF: 57 Zugriffe HTML: 25 Zugriffe PDF: 29 Zugriffe Startseite: 2 Zugriffe HTML: 31 Zugriffe PDF: 49 Zugriffe Startseite: 8 Zugriffe HTML: 40 Zugriffe PDF: 74 Zugriffe Startseite: 2 Zugriffe HTML: 28 Zugriffe PDF: 60 Zugriffe Startseite: 1 Zugriffe HTML: 34 Zugriffe PDF: 80 Zugriffe Startseite: 1 Zugriffe HTML: 34 Zugriffe PDF: 60 Zugriffe Startseite: 3 Zugriffe HTML: 30 Zugriffe PDF: 33 Zugriffe HTML: 25 Zugriffe PDF: 43 Zugriffe Startseite: 1 Zugriffe HTML: 24 Zugriffe PDF: 46 Zugriffe Startseite: 4 Zugriffe HTML: 20 Zugriffe PDF: 45 Zugriffe HTML: 25 Zugriffe PDF: 38 Zugriffe Startseite: 5 Zugriffe HTML: 32 Zugriffe PDF: 36 Zugriffe Startseite: 2 Zugriffe HTML: 17 Zugriffe PDF: 35 Zugriffe Startseite: 9 Zugriffe HTML: 31 Zugriffe PDF: 38 Zugriffe Startseite: 7 Zugriffe HTML: 39 Zugriffe PDF: 42 Zugriffe Startseite: 3 Zugriffe HTML: 33 Zugriffe PDF: 39 Zugriffe Startseite: 10 Zugriffe HTML: 55 Zugriffe PDF: 56 Zugriffe Startseite: 3 Zugriffe HTML: 44 Zugriffe PDF: 33 Zugriffe Startseite: 3 Zugriffe HTML: 48 Zugriffe PDF: 71 Zugriffe Startseite: 9 Zugriffe HTML: 46 Zugriffe PDF: 37 Zugriffe Startseite: 8 Zugriffe HTML: 44 Zugriffe PDF: 60 Zugriffe Startseite: 7 Zugriffe HTML: 35 Zugriffe PDF: 61 Zugriffe Startseite: 6 Zugriffe HTML: 23 Zugriffe
Jul
11
Aug
11
Sep
11
Oct
11
Nov
11
Dec
11
Jan
12
Feb
12
Apr
12
May
12
Jun
12
Jul
12
Aug
12
Sep
12
Oct
12
Nov
12
Dec
12
Jan
13
Feb
13
Mar
13
Apr
13
May
13
Jun
13
Jul
13
Aug
13
Sep
13
Oct
13
Nov
13
Dec
13
Jan
14
Feb
14
Mar
14
Apr
14
May
14
Jun
14
Jul
14
Monat Jul
11
Aug
11
Sep
11
Oct
11
Nov
11
Dec
11
Jan
12
Feb
12
Apr
12
May
12
Jun
12
Jul
12
Aug
12
Sep
12
Oct
12
Nov
12
Dec
12
Jan
13
Feb
13
Mar
13
Apr
13
May
13
Jun
13
Jul
13
Aug
13
Sep
13
Oct
13
Nov
13
Dec
13
Jan
14
Feb
14
Mar
14
Apr
14
May
14
Jun
14
Jul
14
Startseite 2     2 1   12 13 2 3 4 1 1   2 8 2 1 1 3   1 4   5 2 9 7 3 10 3 3 9 8 7 6
HTML 22 21 23 30 29 38 45 56 35 43 34 40 26 25 31 40 28 34 34 30 25 24 20 25 32 17 31 39 33 55 44 48 46 44 35 23
PDF 27 30 39 31 30 26 52 39 42 28 58 46 57 29 49 74 60 80 60 33 43 46 45 38 36 35 38 42 39 56 33 71 37 60 61  

Gesamtzahl der Zugriffe seit Jul 2011:

  • Startseite – 135 (3.75 pro Monat)
  • HTML – 1205 (33.47 pro Monat)
  • PDF – 1570 (43.61 pro Monat)
 
 
Generiert am 01.08.2014, 12:04:57