edoc-Server der Humboldt-Universität zu Berlin

Dissertation

Autor(en): Steffen Huber
Titel: Optimierung der koronaren Plaquedarstellung in der Magnetresonanztomographie
Gutachter: Eckard Fleck; Joerg Barkhausen; Matthias Stuber
Erscheinungsdatum: 02.03.2005
Volltext: html (urn:nbn:de:kobv:11-10039951)
pdf (urn:nbn:de:kobv:11-10039425)
xml (urn:nbn:de:kobv:11-10039967)
Fachgebiet(e): Medizin
Schlagwörter (ger): Magnetresonanztomographie, Herz, Plaque, Navigator, Spiral-Technik, Koronararterie
Schlagwörter (eng): magnetic resonance imaging, plaque, heart, navigator, spiral technique, coronary artery
Einrichtung: Humboldt-Universität zu Berlin, Medizinische Fakultät - Universitätsklinikum Charité
Zitationshinweis: Huber, Steffen: Optimierung der koronaren Plaquedarstellung in der Magnetresonanztomographie; Dissertation, Humboldt-Universität zu Berlin, Medizinische Fakultät - Universitätsklinikum Charité , publiziert am 02.03.2005, urn:nbn:de:kobv:11-10039967
Metadatenexport: Um den gesamten Metadatensatz im Endnote- oder Bibtex-Format zu speichern, klicken Sie bitte auf den entsprechenden Link. Endnote   Bibtex  
print on demand: Wenn Sie auf dieses Icon klicken, können Sie ein Druckexemplar dieser Publikation bestellen.
Diese Seite taggen: Diese Icons führen auf so genannte Social-Bookmark-Systeme, auf denen Sie Lesezeichen anlegen, persönliche Tags vergeben und Lesezeichen anderer Nutzer ansehen können.
  • connotea
  • del.icio.us
  • Furl
  • RawSugar

Abstract (ger):
Die Plaqueruptur in der Koronararterie ist nach heutiger Vorstellung Ursache des akute Koronarsyndrom. Ziel der Arbeit war die Optimierung der koronaren Plaquedarstellung in der Magnetresonanztomographie. Um dieses Ziel zu erreichen, wurden zwei spezifische Probleme der koronaren Plaquedarstellung bearbeitet: Erstens die ateminduzierte Herzbewegung und zweitens die hohe Auflösung, die erforderlich ist, um Plaques in den Koronarien darstellen zu können. Die prospektive Navigator-Gating-Technik wird eingesetzt, um ateminduzierte Artefakte der Herzbewegungen zu korrigieren. Die Herzbewegung wird dabei anhand der craniocaudalen Bewegung des Diaphragmas korrigiert. Durch Unterschiedliche Lagerung des Probanden wurde versucht, die Bewegung des Herzens während der Atmung zu minimieren und die anteroposteriore Komponente der Atmung, die nicht korrigiert werden kann, zu unterdrücken. Die Bewegungsmessungen wurden mit Navigatoren durchgeführt. Die extrem hohen Auflösungen die für eine Plaquedarstellung erforderlich sind erzeugen, durch das geringe Volumen was pro Voxel angeregt wird, sehr wenig Signal. Durch den Einsatz der Spiral-Technik kann theoretisch mehr Signal erzeugt werden. Es wurden Plaquedarstellung der Karotiden und der Koronarien in konventioneller Technik und in Spiral -Technik durchgeführt und das Signal und Kontrast zu Rauschverhältnis verglichen. Das Ergebnis der Bewegungsmessung des Herzens war, dass die Rückenlage die beste Lagerungsmethode für die prospektive Navigator-Gating-Technik ist. Die Plaquedarstellung in den Karotiden zeigte ein statistisch signifikant höheres Signal und Kontrast zu Rauschverhältnis in Spiral-Technik als in konventioneller Technik. Eine Plaquedarstellung in den Koronarien war mit einer Auflösung von 0,273mm mal 0,273mm bei einer Schichtdicke von 0,2mm nur in Spiraltechnik möglich.
Abstract (eng):
The main cause of the acute coronary syndrome is plaque rupture. The aim of the study was to optimize magnetic resonance coronary plaque imaging. To achieve this goal tow specific problems of coronary plaque imaging were investigated. First the heart motion during breathing and second the high spatial resolution, which is necessary to display coronary plaque. The prospective navigator gating technique is used in cardiac magnetic resonance to suppress respiratory motion of the heart. The respiratory heart motion is corrected on the basis of the feed to head motion of the diaphragm. Different patient position were tested to suppress the anterior posterior breathing motion of the heart, because this motion component can not be corrected for. The motion measurements were done with navigators. High spatial resolutions result in a low signal. The spiral technique acquires theoretical more signal than standard techniques. Plaque imaging of the carotid arteries and the coronary arteries were done in spiral and in standard technique. The signal to noise were compared for both techniques. The results of the motion measurements of the heart were: the supine position should be preferred in cardiac magnetic resonance imaging. The spiral technique in the carotid arteries had a significant higher signal to noise ration compared to the standard technique. Coronary plaque imaging was only possible in spiral technique, with a resolution of 0.273 times 0.273mm and slice thickness of 0.2mm.
Zugriffsstatistik: Die Daten für die Zugriffsstatistik der einzelnen Dokumente wurden aus den durch AWStats aggregierten Webserver-Logs erstellt. Sie beziehen sich auf den monatlichen Zugriff auf den Volltext sowie auf die Startseite. Die Zugriffsstatistik wird nicht standardisiert erfasst und kann maschinelle Zugriffe enthalten.
 
Bei Formatversionen eines Dokuments, die aus mehreren Dateien bestehen (insbesondere HTML), wird jeweils der monatlich höchste Zugriffswert auf eine der Dateien (Kapitel) des Dokuments angezeigt.
 
Um die detaillierten Zugriffszahlen zu sehen, fahren Sie bitte mit dem Mauszeiger über die einzelnen Balken des Diagramms.
Startseite: 4 ZugriffeHTML: 300 ZugriffePDF: 4 ZugriffeStartseite: 10 ZugriffeHTML: 138 ZugriffePDF: 6 ZugriffeStartseite: 1 ZugriffeHTML: 103 ZugriffePDF: 2 ZugriffeStartseite: 5 ZugriffeHTML: 163 ZugriffePDF: 7 ZugriffeStartseite: 3 ZugriffeHTML: 286 ZugriffePDF: 9 ZugriffeStartseite: 7 ZugriffeHTML: 267 ZugriffePDF: 10 ZugriffeStartseite: 4 ZugriffeHTML: 257 ZugriffePDF: 6 ZugriffeStartseite: 6 ZugriffeHTML: 246 ZugriffePDF: 9 ZugriffeStartseite: 9 ZugriffeHTML: 283 ZugriffePDF: 3 ZugriffeStartseite: 2 ZugriffeHTML: 240 ZugriffePDF: 4 ZugriffeStartseite: 6 ZugriffeHTML: 247 ZugriffePDF: 6 ZugriffeStartseite: 4 ZugriffeHTML: 224 ZugriffePDF: 10 ZugriffeStartseite: 1 ZugriffeHTML: 238 ZugriffePDF: 10 ZugriffeHTML: 231 ZugriffePDF: 6 ZugriffeHTML: 229 ZugriffePDF: 12 ZugriffeStartseite: 5 ZugriffeHTML: 407 ZugriffePDF: 12 ZugriffeStartseite: 1 ZugriffeHTML: 243 ZugriffePDF: 4 ZugriffeHTML: 246 ZugriffePDF: 14 ZugriffeStartseite: 3 ZugriffeHTML: 115 ZugriffePDF: 13 Zugriffe
Jun
11
Jul
11
Aug
11
Sep
11
Oct
11
Nov
11
Dec
11
Feb
12
Apr
12
May
12
Jun
12
Jul
12
Aug
12
Sep
12
Oct
12
Nov
12
Dec
12
Jan
13
Apr
13

MonatJun
11
Jul
11
Aug
11
Sep
11
Oct
11
Nov
11
Dec
11
Feb
12
Apr
12
May
12
Jun
12
Jul
12
Aug
12
Sep
12
Oct
12
Nov
12
Dec
12
Jan
13
Apr
13
Startseite41015374692641  51 3
HTML300138103163286267257246283240247224238231229407243246115
PDF46279106934610106121241413

Gesamtzahl der Zugriffe seit Jun 2011:

  • Startseite – 71 (3.74 pro Monat)
  • HTML – 4463 (234.89 pro Monat)
  • PDF – 147 (7.74 pro Monat)
  •  
 
Generiert am 22.05.2013, 15:08:43