Logo of Humboldt-Universität zu BerlinLogo of Humboldt-Universität zu Berlin
edoc-Server
Open-Access-Publikationsserver der Humboldt-Universität
de|en
Header image: facade of Humboldt-Universität zu Berlin
View Item 
  • edoc-Server Home
  • Artikel und Monographien
  • Zweitveröffentlichungen
  • View Item
  • edoc-Server Home
  • Artikel und Monographien
  • Zweitveröffentlichungen
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.
All of edoc-ServerCommunity & CollectionTitleAuthorSubjectThis CollectionTitleAuthorSubject
PublishLoginRegisterHelp
StatisticsView Usage Statistics
All of edoc-ServerCommunity & CollectionTitleAuthorSubjectThis CollectionTitleAuthorSubject
PublishLoginRegisterHelp
StatisticsView Usage Statistics
View Item 
  • edoc-Server Home
  • Artikel und Monographien
  • Zweitveröffentlichungen
  • View Item
  • edoc-Server Home
  • Artikel und Monographien
  • Zweitveröffentlichungen
  • View Item
2009-10-11Zeitschriftenartikel DOI: 10.1515/CCLM.2010.044
Experimental validation of specificity of the squamous cell carcinoma antigen-immunoglobulin M (SCCA-IgM) assay in patients with cirrhosis
Zuin, Jessica
Veggiani, Gianluca
Pengo, Paolo
Biasiolo, Alessandra
Tono, Natascia
Gatta, Angelo
Pontisso, Patrizia
Toth, Radovan
Cerin, Dean
Frecer, Vladimir
Meo, Sabrina
Gion, Massimo
Fassina, Giorgio
Beneduce, Luca
Background: Squamous cell carcinoma antigen-immunoglobulin M (SCCA-IgM) is a useful biomarker for the risk of development of hepatocellular carcinoma (HCC) in patients with cirrhosis due to its progressive increase associated to HCC evolution. In patients with cirrhosis, other assays have been affected by interfering reactivities of IgM. In this study, the analytical specificity of the SCCA-IgM assay was assessed by evaluating SCCA-IgM measurement dependence on different capture phases, and by measuring the recovery of SCCA-IgM reactivity following serum fractionation. Methods: Serum samples from 82 patients with cirrhosis were analyzed. SCCA-IgM was measured using the reference test (Hepa-IC, Xeptagen, Italy) that is based on rabbit oligoclonal anti-squamous cell carcinoma antigen (SCCA) and a dedicated ELISA with a mouse monoclonal anti-SCCA as the capture antibody. Results: SCCA-IgM concentrations measured with the reference assay (median value=87 AU/mL) were higher than those measured with the mouse monoclonal test (median value=78 AU/mL). However, the differences in the SCCA-IgM distribution were not statistically significant (p>0.05). When SCCA-IgM concentrations measured with both tests were compared, a linear correlation was found (r=0.77, p<0.05). Fractionation of the most reactive sera by gel-filtration chromatography showed that total recovery of SCCA-IgM reactivity was seen only in the fractions corresponding to components with a molecular weight higher than IgM and SCCA (>2000 kDa) with both tests. Conclusions: The equivalence of both SCCA-IgM assays and the absence of reactivity not related to immune complexes support the analytical specificity of SCCA-IgM measurements. The results validate the assessment of SCCA-IgM for prognostic purposes in patients with cirrhosis. Clin Chem Lab Med 2010;48:217–23.
Files in this item
Thumbnail
cclm.2010.044.pdf — Adobe PDF — 194.0 Kb
MD5: 1eaaabfc907f6af77929a3fcc437c42f
Cite
BibTeX
EndNote
RIS
InCopyright
Details
DINI-Zertifikat 2019OpenAIRE validatedORCID Consortium
Imprint Policy Contact Data Privacy Statement
A service of University Library and Computer and Media Service
© Humboldt-Universität zu Berlin
 
DOI
10.1515/CCLM.2010.044
Permanent URL
https://doi.org/10.1515/CCLM.2010.044
HTML
<a href="https://doi.org/10.1515/CCLM.2010.044">https://doi.org/10.1515/CCLM.2010.044</a>