Show simple item record

2009-06-08Zeitschriftenartikel DOI: 10.18452/11410
A new obstetrical polyurethane versus stainless steel forceps: a comparison of forces generated to the base of the fetal skull during simulated deliveries
dc.contributor.authorHale, Theodore M.
dc.contributor.authorShi, Zhengzhuan
dc.contributor.authorIdangodage, Hasitha
dc.contributor.authorMercado, Ray
dc.contributor.authorSkupski, Daniel
dc.contributor.authorVeilastegui, Zoila
dc.date.accessioned2017-06-17T07:51:15Z
dc.date.available2017-06-17T07:51:15Z
dc.date.created2010-07-01
dc.date.issued2009-06-08
dc.identifier.issn1619-3997
dc.identifier.urihttp://edoc.hu-berlin.de/18452/12062
dc.description.abstractBackground: Decreasing the maximum force applied during traction to the base of the fetal skull using a less rigid polyurethane forceps is the basis of this study. Our hypothesis was that less force would be generated with polyurethane forceps than with steel forceps. Objective: To test a new soft polyurethane obstetrical forceps for maximal force generated to the base of the skull during simulated occiput anterior deliveries and to compare this to a similar shaped steel forceps. Methods: After designing a prototype polyurethane forceps, we used a pelvic manikin model and a fetal manikin model. Force and load sensors were attached at the inner tips of the distal forceps blade. A Tekscan 201 (accurate for measuring 0–25 pounds of force) 0.0008 inches flexible printed circuit was used that measured contact forces. Forceps with an attached calibrated sensor were applied to the fetal head while inside the pelvic model. Results: The median maximum traction force at the base of the fetal skull was 4.60 pounds (range 4.3–4.62) for polyurethane forceps vs. 9.52 pounds (range 9.22–9.52) for steel forceps (P=0.027). Conclusion: The polyurethane forceps applied 50% less overall mechanical force than the steel forceps at the tip of the forceps and base of the skull during simulated occiput anterior outlet deliveries.eng
dc.language.isound
dc.publisherKooperation de Gruyter
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/
dc.titleA new obstetrical polyurethane versus stainless steel forceps: a comparison of forces generated to the base of the fetal skull during simulated deliveries
dc.typearticle
dc.identifier.urnurn:nbn:de:kobv:11-100143004
dc.identifier.doihttp://dx.doi.org/10.18452/11410
local.edoc.type-nameZeitschriftenartikel
local.edoc.container-typeperiodical
local.edoc.container-type-nameZeitschrift
local.edoc.container-year2009
dc.description.versionPeer Reviewed
dcterms.bibliographicCitation.doi10.1515/JPM.2009.136
dcterms.bibliographicCitation.journaltitleJournal of Perinatal Medicine
dcterms.bibliographicCitation.volume37
dcterms.bibliographicCitation.issue6
dcterms.bibliographicCitation.originalpublishernamede Gruyter
dcterms.bibliographicCitation.pagestart669
dcterms.bibliographicCitation.pageend671

Show simple item record