Show simple item record

2002-10-29Habilitation DOI: 10.18452/13828
Evaluation neuer radiologischer Bildgebungstechniken in der otologischen Diagnostik
dc.contributor.authorKlingebiel, Randolf
dc.date.accessioned2017-06-18T00:10:59Z
dc.date.available2017-06-18T00:10:59Z
dc.date.created2002-10-01
dc.date.issued2002-10-29
dc.identifier.urihttp://edoc.hu-berlin.de/18452/14480
dc.description.abstractDie Optimierung der Akquisitionstechniken führte zu einer verbesserten Abgrenzbarkeit klinisch relevanter Bilddetails und war gleichzeitig Voraussetzung für die Erzeugung bildqualitativ hochwertiger dreidimensionaler Bildrekonstruktionen. Die Kombination aus hochauflösenden Akquisitionstechniken und der dreidimensionalen Visualisierung mittels Volume Rendering ermöglichte die nicht-invasive endoluminale Darstellung im Sinne einer virtuellen Oto- bzw. Neuroendoskopie. Trotz weitgehender Übereinstimmung zwischen der realen und virtuell dargestellten Pathomorphologie ossikulärer Strukturen in der Mittelohr-Bildgebung zeigten sich methodische Limitationen in der Erfassung der Pathophysiologie. Die 3D-Bildgebung des Innenohrs gewährleistete eine detaillierte Darstellung pathoanatomisch komplexer Veränderungen und erlaubte dadurch Rückschlüsse auf die Pathogenese. Insbesondere in der Bildgebung des Mittelohrs und Kleinhirn-Brückenwinkels erwiesen sich die virtuell-endoskopischen Ansichten als komplementäre Darstellungstechniken, deren Ergebnisse im Zusammenhang mit den primären Schnittbilddaten und den klinischen Untersuchungsergebnissen zu interpretieren sind. Prospektiv ist aufgrund neuer Gerätetechnologien in der Bilddaten-Erfassung (z.B. 16-Schicht-Spiral-CT) sowie höheren Rechnerleistungen in der Daten-Nachverarbeitung von einer zunehmenden Verbreitung dreidimensionaler Bildgebungstechniken auszugehen.ger
dc.description.abstractOptimized data acquisition resulted in an improved delineation of critical image elements and was a prerequisite for generating 3D reconstructions of high image quality. Combining high-resolution data acquisition and 3D visualization by means of volume rendering allowed for the noninvasive endoluminal assessment known as virtual oto- and neuroendoscopy. Despite a high degree of agreement between the intraoperatively verified ossicular pathomorphology and that visualized by virtual otoscopy in middle ear imaging methodological limitations were encountered with respect to pathophysiological evaluation. 3D imaging provided detailed views of even complex pathoanatomical conditions, thus permitting conclusions regarding the underlying pathogenesis. As far as imaging of the middle ear and cerebellopontine angle was concerned, virtual endoscopic views proved to be complementary visualization techniques whose results have to be interpreted in the context of the primary cross-sectional data and clinical findings. Prospectively, a more widespread use of 3D imaging techniques may be expected from upcoming acquisition technologies (for example 16-slice helical CT) as well as from more powerful computers with improved image data postprocessing capacities.eng
dc.language.isoger
dc.publisherHumboldt-Universität zu Berlin, Medizinische Fakultät - Universitätsklinikum Charité
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/
dc.subjectMRTger
dc.subjectMittelohrger
dc.subjectInnenohrger
dc.subjectCTger
dc.subjectMRIeng
dc.subjectCTeng
dc.subjectmiddle eareng
dc.subjectinner eareng
dc.subject.ddc610 Medizin und Gesundheit
dc.titleEvaluation neuer radiologischer Bildgebungstechniken in der otologischen Diagnostik
dc.typedoctoralThesis
dc.identifier.urnurn:nbn:de:kobv:11-10023918
dc.identifier.urnurn:nbn:de:kobv:11-10039887
dc.identifier.urnurn:nbn:de:kobv:11-10039898
dc.identifier.doihttp://dx.doi.org/10.18452/13828
dc.date.accepted2002-10-01
dc.contributor.refereeBecker, H.
dc.contributor.refereeMüdder, U.
dc.subject.dnb33 Medizin
dc.subject.rvkXH 2900
local.edoc.pages136
local.edoc.type-nameHabilitation
bua.departmentMedizinische Fakultät - Universitätsklinikum Charité

Show simple item record