Logo of Humboldt-Universität zu BerlinLogo of Humboldt-Universität zu Berlin
edoc-Server
Open-Access-Publikationsserver der Humboldt-Universität
de|en
Header image: facade of Humboldt-Universität zu Berlin
View Item 
  • edoc-Server Home
  • Artikel und Monographien
  • Zweitveröffentlichungen
  • View Item
  • edoc-Server Home
  • Artikel und Monographien
  • Zweitveröffentlichungen
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.
All of edoc-ServerCommunity & CollectionTitleAuthorSubjectThis CollectionTitleAuthorSubject
PublishLoginRegisterHelp
StatisticsView Usage Statistics
All of edoc-ServerCommunity & CollectionTitleAuthorSubjectThis CollectionTitleAuthorSubject
PublishLoginRegisterHelp
StatisticsView Usage Statistics
View Item 
  • edoc-Server Home
  • Artikel und Monographien
  • Zweitveröffentlichungen
  • View Item
  • edoc-Server Home
  • Artikel und Monographien
  • Zweitveröffentlichungen
  • View Item
2020-01-06Zeitschriftenartikel DOI: 10.18452/21066
A simple MALDI target plate with channel design to improve detection sensitivity and reproducibility for quantitative analysis of biomolecules
Liu, Zhen
Zhang, Peng cc
Kästner, Lars
Volmer, Dietrich cc
Mathematisch-Naturwissenschaftliche Fakultät
Overcoming the detrimental effects of sweet spots during crystallization is an important step to improve the quantitative abilities of matrix‐assisted laser desorption/ionization (MALDI) mass spectrometry. In this study, we introduce MALDI targets, which exhibit a channel design to reduce sweet spot phenomena and improve reproducibility. The size of the channels was 3.0 mm in length, 0.35 mm in depth, and 0.40 mm in width, adjusted to the width of the implemented laser beam. For sample deposition, the matrix/sample mixture was homogenously deposited into the channels using capillary action. To demonstrate the proof‐of‐principle, the novel plates were used for the quantification of acetyl‐L‐carnitine in human blood plasma using a combined standard addition and isotope dilution method. The results showed that the reproducibility of acetyl‐L‐carnitine detection was highly improved over a conventional MALDI‐MS assay, with RSD values of less than 5.9% in comparison with 15.6% using the regular MALDI method. The limits of quantification using the new plates were lowered approximately two‐fold in comparison with a standard rastering approach on a smooth stainless‐steel plate. Matrix effects were also assessed and shown to be negligible. The new assay was subsequently applied to the quantification of acetyl‐L‐carnitine in human plasma samples.
Files in this item
Thumbnail
Liu_et_al-2019-Journal_of_Mass_Spectrometry.pdf — Adobe PDF — 3.160 Mb
MD5: 365a008baaffcb6582d4a8d60ac002e9
Cite
BibTeX
EndNote
RIS
(CC BY 4.0) Attribution 4.0 International(CC BY 4.0) Attribution 4.0 International
Details
DINI-Zertifikat 2019OpenAIRE validatedORCID Consortium
Imprint Policy Contact Data Privacy Statement
A service of University Library and Computer and Media Service
© Humboldt-Universität zu Berlin
 
DOI
10.18452/21066
Permanent URL
https://doi.org/10.18452/21066
HTML
<a href="https://doi.org/10.18452/21066">https://doi.org/10.18452/21066</a>