Logo of Humboldt-Universität zu BerlinLogo of Humboldt-Universität zu Berlin
edoc-Server
Open-Access-Publikationsserver der Humboldt-Universität
de|en
Header image: facade of Humboldt-Universität zu Berlin
View Item 
  • edoc-Server Home
  • Artikel und Monographien
  • Zweitveröffentlichungen
  • View Item
  • edoc-Server Home
  • Artikel und Monographien
  • Zweitveröffentlichungen
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.
All of edoc-ServerCommunity & CollectionTitleAuthorSubjectThis CollectionTitleAuthorSubject
PublishLoginRegisterHelp
StatisticsView Usage Statistics
All of edoc-ServerCommunity & CollectionTitleAuthorSubjectThis CollectionTitleAuthorSubject
PublishLoginRegisterHelp
StatisticsView Usage Statistics
View Item 
  • edoc-Server Home
  • Artikel und Monographien
  • Zweitveröffentlichungen
  • View Item
  • edoc-Server Home
  • Artikel und Monographien
  • Zweitveröffentlichungen
  • View Item
2022-08-05Zeitschriftenartikel DOI: 10.1088/1748-0221/17/08/P08004
Characterization of a CdZnTe detector for a low-power CubeSat application
Lucchetta, Giulio cc
Ackermann, Markus cc
Berge, David cc
Bloch, Ingo cc
Bühler, Rolf
Kolanoski, Hermann
Lange, Wolfgang
Zappon, Francesco
Mathematisch-Naturwissenschaftliche Fakultät
We report spectral and imaging performance of a pixelated CdZnTe detector custom designed for the MeVCube project: a small Compton telescope on a CubeSat platform. MeVCube is expected to cover the energy range between 200 keV and 4 MeV, with a sensitivity comparable to the one of the last generation of larger satellites. In order to achieve this goal, an energy resolution of few percent in full width at half maximum (FWHM) and a 3-D spatial resolution of few millimeters for the individual detectors are needed. The severe power constraints present in small satellites require very low power read-out electronics for the detector. Our read-out is based on the VATA450.3 ASIC developed by Ideas, with a power consumption of only 0.25 mW/channel, which exhibits good performance in terms of dynamic range, noise and linearity. A 2.0 cm× 2.0 cm× 1.5 cm CdZnTe detector, with a custom 8 × 8 pixel anode structure read-out by a VATA450.3 ASIC, has been tested. A preliminary read-out system for the cathode, based on a discrete Amptek A250F charge sensitive pre-amplifier and a DRS4 ASIC, has been implemented. An energy resolution around 3% FWHM has been measured at a gamma energy of 662 keV; at 200 keV the average energy resolution is 6.5%, decreasing to ≲ 2% at energies above 1 MeV. A 3-D spatial resolution of ≈ 2 mm is achieved in each dimension.
Files in this item
Thumbnail
jinst_17_08_P08004.pdf — Adobe PDF — 3.342 Mb
MD5: 0d1404332dfb5661236eb2dcb4be12bf
Cite
BibTeX
EndNote
RIS
(CC BY 4.0) Attribution 4.0 International(CC BY 4.0) Attribution 4.0 International
Details
DINI-Zertifikat 2019OpenAIRE validatedORCID Consortium
Imprint Policy Contact Data Privacy Statement
A service of University Library and Computer and Media Service
© Humboldt-Universität zu Berlin
 
DOI
10.1088/1748-0221/17/08/P08004
Permanent URL
https://doi.org/10.1088/1748-0221/17/08/P08004
HTML
<a href="https://doi.org/10.1088/1748-0221/17/08/P08004">https://doi.org/10.1088/1748-0221/17/08/P08004</a>